Precision-engineered thermal break profiles designed for Belgian commercial projects, luxury villas, and high-performance building envelopes.
Understanding the strict thermal, acoustic, and environmental criteria required by Belgian building codes across Flanders, Wallonia, and Brussels-Capital Region.
Belgian regional regulations impose stringent overall heat transfer coefficients ($U_{max}$). Commercial window elements require frame thermal transmittance ($U_f$) values down to 1.0–1.4 W/m²K, while entire fenestration units ($U_w$) must hit ≤0.85 W/m²K for Passive House projects in Brussels and Flanders. Our engineered polyamide multi-chamber thermal breaks bridges meet these targets effortlessly.
Projects along the North Sea coast (Ostend, Zeebrugge, Knokke-Heist) experience extreme wind velocity and dynamic rain load pressure. Our curtain walls and lifting-sliding systems undergo rigorous EN 12211 testing to ensure resistance up to wind pressures of 2400 Pa (Class C5/B5) and EN 1027 watertightness up to E1500 exceptional ratings.
Belgium’s strict acoustic norm NBN S 01-400-1 sets specific decibel decay goals for commercial office towers and mixed-use apartments near railway corridors (Brussels North-South connection, Antwerp Central). Utilizing multi-layer acoustic laminated glass with warm-edge spacers, our systems achieve sound reduction indices up to $R_w + C_{tr} = 45\text{ dB}$.
Verified laboratory metrics for engineers, general contractors, and facade consultants.
| System Category | Profile Depth | Thermal Value ($U_w$) | Air Permeability (EN 1026) | Watertightness (EN 1027) | Wind Load (EN 12210) |
|---|---|---|---|---|---|
| Triple-Glazed Lift & Slide | 76mm – 110mm | 0.82 – 1.1 W/m²K | Class 4 (600 Pa) | Class E1200 (1200 Pa) | Class C5 (2000 Pa) |
| Unitized Curtain Wall (EN 13830) | 150mm – 220mm | 0.90 – 1.3 W/m²K | Class AE 1500 Pa | Class RE 1500 Pa | Design Load 2.5 kPa |
| Slim Minimal Structural Glazing | Sightline 20mm | 1.1 – 1.4 W/m²K | Class 4 (600 Pa) | Class 9A (600 Pa) | Class C4 (1600 Pa) |
| Bi-Folding Commercial Facades | 70mm – 85mm | 1.2 – 1.5 W/m²K | Class 4 (600 Pa) | Class E900 (900 Pa) | Class C3 (1200 Pa) |
| Bioclimatic Louvre Systems | Beam 180mm | N/A (Outdoor) | N/A | Integrated Gutter 150l/h/m² | Wind Class 6 (Up to 160km/h) |
From high-density corporate towers in Brussels to heritage conversions in Ghent, our aluminum envelope systems are engineered for diverse micro-climates and architectural aesthetics.
High-rise office buildings in Brussels North Quarter and Leopold Quarter demand pre-assembled unitized curtain wall modules. Factory-fabricated under strict quality control, our unitized systems minimize on-site scaffolding costs, allow fast tower enclosure, and feature integrated solar control glass to reduce interior HVAC loads in summer.
Industrial headquarters and maritime logistics facilities along the Scheldt estuary require heavy-duty corrosion-resistant finishes. We supply Qualicoat Class 2 and "Seaside" anodized aluminum profiles with a minimum anodizing layer of 25 microns, guarding against saline air, industrial pollutants, and aggressive weather wear.
Modern luxury villas and boutique hotels in Flanders demand seamless connections between indoor living spaces and outdoor terraces. Our ultra-slim sliding glass systems feature minimalist 20mm vertical sightlines and flush floor tracks, blending sleek contemporary architecture with extreme airtightness.
Combining Turkey’s advanced aluminum extrusion eco-system with European project supervision, certified standards, and direct door-to-site delivery logistics.
We work directly from your DWG/PDF schedules and BIM models. Our facade engineers evaluate wind load requirements according to Belgian standards (NBN EN 1991-1-4 ANB), verify thermal bridges, and generate custom structural section drawings before production begins.
Under the EU-Turkey Customs Union agreement, our aluminum window and facade shipments enter Belgium with A.TR movement certificates, ensuring 0% customs import duty. This grants Belgian buyers premium European-tested quality at a highly competitive factory-direct price point.
Every fenestration unit is wrapped in protective foam, corner-bracketed, and packaged into ISPM-15 compliant fumigated wooden crates. Crates are clearly labeled by building elevation codes, allowing efficient floor-by-floor unloading at job sites in Antwerp or Brussels.
Clear answers regarding technical certifications, shipping terms, glass specifications, and EPB software compliance.
Yes. All profiles and fabricated window/curtain wall units carry CE marking under EN 14351-1 (Windows and Doors) and EN 13830 (Curtain Walls). Factory extruded profiles comply with EN 12020-2 dimensional tolerances. Full test dossiers including EN 1026 air permeability, EN 1027 water tightness, and EN 12211 wind load test reports are provided for submission to Belgian building control authorities.
Absolutely. We provide project-specific thermal calculation dossiers prepared in accordance with EN ISO 10077-1 and EN ISO 10077-2. We supply exact frame values ($U_f$), glass center-of-glass values ($U_g$), linear thermal bridge values ($\Psi$), and frame ratio metrics required by EPB reporters in Flanders, Wallonia, and Brussels.
Manufacturing and shop drawing approvals typically require 3 to 4 weeks depending on project complexity. Sea freight transit from Turkish ports (Istanbul, Izmir) to the Port of Antwerp takes approximately 10 to 14 days. Direct truck transport across continental Europe delivers directly to job sites in Brussels or Ghent within 5 days.
We integrate premier European hardware brands including ROTO Frank, STAC, Sobinco, and G-U for multi-point tilt-and-turn and lift-and-slide mechanisms. Glazing options include Saint-Gobain or AGC double and triple glass units with Low-E coatings, warm-edge spacers, and solar control glass tailored to European climate orientations.
For coastal applications in Ostend, Zeebrugge, or Knokke, we utilize Qualicoat "Seaside" certified powder coating pre-treatment or 25-micron anodization (Qualanod). This multi-stage chemical etching process prevents filiform corrosion and guarantees high UV color retention over decades of exposure to harsh marine environments.
Upload your architectural elevations, DWG schedules, or tender documents. Our facade engineering team will calculate your $U_w$ values, verify wind loads, and return a comprehensive bill of quantities within 72 hours.